Dichotic Sentence Identification | Warner Tech-care Products
Auditec Auditory Test Dichotic Sentence Identification
Have an account with us?
Login to see prices and add items to your cart.
Login to AccountDon't have an account?
Contact Warner Tech-care today!The Dichotic Sentence Identification© (DSI) test is for binaural separation. It was developed to conceive a dichotic listening task that would be only minimally affected by peripheral hearing loss. Sentences selected are presented dichotically. Onsets and offsets of the sentences are aligned with an accuracy of 100 microseconds. The developer contends the DSI is less susceptible to hearing loss than the SSW test. The DSI is a viable test of central auditory function in the hearing impaired population. The test is applicable for use in auditory assessment of impaired ears through pure tone averages (PTAs) up to 50 dB at least. The DSI is made up of two sets of 30 pairs of sentences. Administration time is approximately 12 minutes.
The Dichotic Sentence Identification includes a) audio recording, and b) instructions and score forms as printable pdf files. The three-page instructions consist of administration, scoring, and interpretation information. Normative data is included for adults only. It would be reasonable to expect children over the age of eleven to test as well (or nearly as well) as adults.